    RS485 Output water level sensor Sewage Pool PTFE Low cost intelligent 20khz ultrasonic transducer

    Ask Lasest Price
    Brand Name : Kacise
    Model Number : KUS550
    Certification : certificate of explosion-proof, CE
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram,paypal
    Supply Ability : 10000 Pieces per month
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    RS485 Output water level sensor Sewage Pool PTFE Low cost intelligent 20khz ultrasonic transducer


    KUS550 Ultrasonic Distance Sensor


    1. Product features:

    • High sensitivity.
    • Compact and robust structure.
    • IP68 high protection rating.
    • Corrosion resistant casing, suitable for corrosive medium and application

    2.Application

    • Tank level measurement
    • Bin level measurement
    • Proximity zone detection
    • People detection
    • Robot ranging sensor
    • Autonomous navigation
    • Multi-sensors navigation
    • Distance measuring
    • Long range object detection
    • Industrial automation


    3. Product Description


    This sensor provides very short to long-range detection and ranging, in a compact, robust PVC housing,
    designed to meet IP65.

    4. Parameter

    (1)General specifications

    Model: KUS550
    Measuring range

    0.25m~3m (5m customizable)KUS550A

    0.15m-0.6m(1m customizable)KUS550B;

    Blind spotThe dead zone of KUS550A is 0 ... 250 mm (within 250mm is unstable working zone, it is not recommended to work in this range); the dead zone of KUS550B is 0-150mm;
    Supply voltage3.3 ... 30 VDC, ripple 10 %SS
    Working current≤ 45 mA (fastest measurement speed), typical power consumption ≤ 10 mA;
    Output signal0-10V. 0-3V 0-5V /4-20mA/NPN/PNP/RS485 Analog output.
    Measurement accuracy≤1 %F.S.
    Temperature compensationYes
    Ranging resolution0.1mm;

    (2)Working conditions

    Working temperature-40…85℃ (233...358K)
    Storage temperature-40…85℃ (233...358K)

    (3)Other instructions

    Electrical connection5-core cable (analog output), 6-core cable (switch output) .
    Protection classIP68
    Shell materialPVC /PVDF/PTFE/ABS


    5. Dimensions



    6. Wiring



    7.Description of Sensor Functions

    (1)Adjusting the analogue output.

    The analogue output can be programed as the user want. Such as working at switch output or working at liner output all the parameters can be set by the RS485 interface.

    There are 8 types of output functions can be programed.

    All the setting routine as follows,

    step 1 set one pointed distance by the RS485,

    step 2 set another pointed distance by the RS485.

    Step3 set the output type liner or switch, and set the related output options

    Step4 reboot the sensor.

    1. Window mode normally-open and liner mode positive slope output function.

    2. Window mode normally-closed and liner mode negative slope output function.

    3. Single switching point, normally-open function.

    4. Single switching point, normally-closed function.

    5. Single switch point with hysteresis gap normally-open function.

    6. Single switch point with hysteresis gap normally-closed function.

    7. Detection of object presence-normal open function.

    8. Detection of object presence-closed open function.

    Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 minutes after power on. If want to change the switching point, the user can only set the request distance after power restart.

    (2)For the RS485 output type.

    There are 2 kinds of working style,

    One for auto measure, the sensor will measure the distance or level repeatedly, and the measurement period can be set by the UART. The measure result can be fetched every time.

    The other style is power save mode when the sensor is sleep, until the sensor received the inquiry command with pre-code. Communication protocol is Modus-RTU.

    For example, the measure result can be read by access the register 0x101 by Modbus protocol.

    For more information please contact us for the software engineering guide.

    Quality RS485 Output water level sensor Sewage Pool PTFE Low cost intelligent 20khz ultrasonic transducer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)