Sign In | Join Free | My himfr.com
Home > Precision Pressure Sensor >

Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range

    Buy cheap Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range from wholesalers
     
    Buy cheap Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range from wholesalers
    • Buy cheap Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range from wholesalers
    • Buy cheap Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range from wholesalers
    • Buy cheap Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range from wholesalers
    • Buy cheap Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range from wholesalers

    Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range

    Ask Lasest Price
    Brand Name : Fluke
    Model Number : 376 FC
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    Certification : CE
    • Product Details
    • Company Profile

    Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range

    Fluke 376 FC True-RMS Clamp Meter with iFlex 2500 A Range 0.1 A Resolution

    Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range

    Technical Specs at a Glance

    General Specifications
    AC Current via Jaw
    Range999.9 A
    Resolution0.1 A
    Accuracy2% ±5 digits (10 Hz to 100 Hz)
    2.5% ±5 digits (100-500 Hz)
    Crest Factor (50 Hz/60 Hz)3 @ 500 A
    2.5 @ 600 A
    Add 2% for C.F. >2
    AC Current via Flexible Current Probe
    Range2500 A
    Resolution0.1 A (≤ 600 A)
    1 A (≤ 2500 A)
    Accuracy3% ±5 digits (5 – 500 Hz)
    Crest Factor (50/60Hz)3.0 at 1100 A
    2.5 at 1400 A
    1.42 at 2500 A
    Add 2% for C.F. > 2


    i2500-10 Flexi2500-18 Flexi2500-36 Flex
    A


    Distance from Optimum0.5 in (12.7 mm)1.4 in (35.6 mm)4.8 in (122.2 mm)
    Error±0.5 %±0.5 %±0.5 %
    B


    Distance from Optimum0.8 in (20.3 mm)2.0 in (50.8 mm)5.3 in (133.6 mm)
    Error±1.0 %±1.0 %±1.0 %
    C


    Distance from Optimum1.4 in (35.6 mm)2.5 in (63.5 mm)5.8 in (147.6 mm)
    Error±2.0 %±2.0 %±2.0 %
    Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
    DC Current
    Range999.9 A
    Resolution0.1 A
    Accuracy2% ±5 digits
    AC Voltage
    Range1000 V
    Resolution0.1 V (≤600.0 V)
    1 V (≤1000 V)
    Accuracy1% ±5 digits (20 Hz to 500 Hz)
    DC Voltage
    Range1000 V
    Resolution0.1 V (≤600.0 V)
    1 V (≤1000 V)
    Accuracy1% ±5 digits
    mV dc
    Range500.0 mV
    Resolution0.1 mV
    Accuracy1% ±5 digits
    Frequency via Jaw
    Range5.0 Hz to 500.0 Hz
    Resolution0.1 Hz
    Accuracy0.5% ±5 digits
    Trigger level5 Hz to 10 Hz, ≥10 A
    10 Hz to 100 Hz, ≥5 A
    100 Hz to 500 Hz, ≥10 A
    Frequency via Flexible Current Probe
    Range5.0 Hz to 500.0 Hz
    Resolution0.1 Hz
    Accuracy0.5% ±5 digits
    Trigger level5 Hz to 20 Hz, ≥25 A
    20 Hz to 100 Hz, ≥20 A
    100 Hz to 500 Hz, ≥25 A


    Quality Fluke 376 FC True-RMS Clamp Meter with iFlex 2500A Range for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)